Data Center Solution

Data Center Power Solution

High-efficiency, low-loss, low-noise transformer solutions for data centers — where reliability, redundancy, and energy efficiency are critical. Cast resin dry-type for indoor fire-safe installation.

Low Loss & Low NoiseFire-safe Dry Type24/7 Critical Loads
Application

Key Requirements for Data Center Transformers

Efficiency

High Efficiency & Low Loss

Ultra-low no-load and load loss — critical for PUE optimization in 24/7 operation. Amorphous core option.

Noise

Low Noise Level

Sound level designed to ≤55dB (typical) for indoor installation near IT equipment rooms.

Thermal

Temperature Rise Control

F/B insulation class with controlled temperature rise for continuous heavy loading.

Harmonic

Harmonic Adaptation

K-factor rated for UPS and server power supply harmonic-rich loads.

Reliability

Redundancy & Reliability

N+1 or 2N configuration support. High-reliability design with extended lifecycle.

Monitoring

Monitoring Interface

Temperature, winding hot-spot, partial discharge monitoring — SCADA/BMS integration.

Delivery

Fast Delivery

Standard configurations available with short lead times for rapid deployment.

Fire-safe

Cast Resin Dry-type

Fire-safe, indoor, self-extinguishing — meets data center fire safety requirements.

Engineering Data

Key Technical Parameters

TypeCast resin dry-type (indoor, fire-safe)
Capacity1000–3150 kVA per unit; parallel for larger loads
Voltage10/20kV → 0.4kV (typical); custom ratios available
Insulation classF (155°C) or H (180°C)
Temperature rise≤100K (F class) or ≤125K (H class)
Sound level≤55dB (typical); ≤50dB available
K-factorK-4 to K-20 for UPS/server harmonic loads
ProtectionIP20 indoor (standard); IP31 available
MonitoringTemperature controller, PD sensor, SCADA interface
System & Equipment View

See how the solution fits together

A focused system view and one relevant equipment detail—without repeating the Hero image.

HUACHEN data center transformer UPS protection and critical load coordination diagram
System Design Drawing

Data Center Power System Coordination

Coordinated relationship between utility or generator, transformer, protection, UPS distribution and critical IT loads.

HUACHEN cast resin dry type transformer details for data centers
Equipment Detail

Fire-safe dry-type transformer detail

Low-noise cast-resin construction designed for indoor installation and continuous critical loading.

RECOMMENDED CONFIGURATION

Data-center power options

Choose a proven starting point, then let our engineers adapt voltage, capacity, impedance, cooling, enclosure and documentation to the project.

Planning a data center?

Tell us your load capacity, redundancy requirements, and efficiency targets. We’ll propose the right transformer configuration.

Request a Solution